Difference between revisions of "FM36YX Device Family Parameter list"
From Wiki Knowledge Base | Teltonika GPS
m (Protected "FM36YX Device Family Parameter list" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
Simkunas.ma (talk | contribs) |
||
(10 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
==Parameters value types== | ==Parameters value types== | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==System parameters== | ==System parameters== | ||
{{Template:FM36_System_Parameters}} | {{Template:FM36_System_Parameters}} | ||
==Records parameters== | ==Records parameters== | ||
− | + | ||
==GSM parameters== | ==GSM parameters== | ||
− | + | ||
==Data aquisition parameters== | ==Data aquisition parameters== | ||
− | + | ||
==Features parameters== | ==Features parameters== | ||
− | + | ||
==I/O parameters== | ==I/O parameters== | ||
− | + | ||
==LV-CAN Features== | ==LV-CAN Features== | ||
− | + | ||
==SMS EVENT CONFIGURATION== | ==SMS EVENT CONFIGURATION== | ||
− | |||
− | |||
− | |||
− |
Revision as of 14:12, 1 June 2018
Main Page > EOL Products > FM3612 > FM3612 Manual > FM36YX Device Family Parameter listParameters value types
System parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1000 | U8 | 0 | 0 | 2 | 0 – Disabled | Sleep Settings |
1 – GPS Sleep | ||||||
2 – Deep Sleep | ||||||
200 | U8 | 1 | 1 | 3000 | - | Sleep Timeout |
1001 | U8 | 0 | 0 | 1 | 0 - 10V | Analog Input value range |
1 – 30V | ||||||
1002 | U8 | 1 | 0 | 3 | 0 - ignition | Stop Detection Source |
1 - Msensor | ||||||
2 - GPS | ||||||
3 - ignition + Msensor | ||||||
1003 | U8 | 0 | 0 | 1 | 0 - Disabled | Static Navigation |
1 – Enabled | ||||||
1004 | 0 | 0 | 2 | 0 – Power voltage | Ignition Source | |
1 – Digital input 1 | ||||||
2 – Msensor | ||||||
1005 | 30000 mV | 13000 mV | 30000 mV | High Voltage Level | ||
1006 | 13000 mV | 0 | 30000 mV | Low Voltage Level | ||
1008 | 0 | 0 | 1 | 0 - Manual | Ignition Detection | |
1 – Automatic | ||||||
1009 | U8 | 10 | 0 | 65535 | Ignition Detection Timeout | |
1007 | U8 | 60 | 0 | 65535 | GNSS FIX Timeout for Time Synchronization via NTP | |
201 | U8 | 0 | 0 | 1 | 0 - Disabled | Saving/Sending without time synchronization |
1 – Enabled | ||||||
202 | U8 | 0 | 0 | 2 | 0 – GNSS (all available) | Satellite System |
1 – GPS | ||||||
2 – GLONASS |