Difference between revisions of "FM36YX Device Family Parameter list"

From Wiki Knowledge Base | Teltonika GPS
m (Protected "FM36YX Device Family Parameter list" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
(10 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 
==Parameters value types==
 
==Parameters value types==
 
*S8 – Signed Char
 
*S8[n] – String of n Char
 
*Uint8 (U8) – Unsigned Char
 
*Uint16 (U16) – Unsigned Short
 
*S32 – Signed Integer
 
*U32 – Unsigned Integer
 
*U64 – Unsigned Long Long Integer
 
  
 
==System parameters==
 
==System parameters==
 
{{Template:FM36_System_Parameters}}
 
{{Template:FM36_System_Parameters}}
 
==Records parameters==
 
==Records parameters==
{{Template:FM36_Records_Parameters}}
+
 
 
==GSM parameters==
 
==GSM parameters==
{{Template:FM36_GSM_Parameters}}
+
 
 
==Data aquisition parameters==
 
==Data aquisition parameters==
{{Template:FM36_Data_aquisition_Parameters}}
+
 
 
==Features parameters==
 
==Features parameters==
{{Template:FM36_Features_Parameters}}
+
 
 
==I/O parameters==
 
==I/O parameters==
{{Template:FM36_I/O_parameters_Parameters}}
+
 
 
==LV-CAN Features==
 
==LV-CAN Features==
{{Template:FM36_LV_CAN_Features}}
+
 
 
==SMS EVENT CONFIGURATION==
 
==SMS EVENT CONFIGURATION==
{{Template:FM36_SMS_Event_Configuration}}
 
[[Category:FM3612 Manual]]
 
[[Category:FM36M1 Manual]]
 
[[Category:FM3622 Manual]]
 

Revision as of 14:12, 1 June 2018

Main Page > EOL Products > FM3612 > FM3612 Manual > FM36YX Device Family Parameter list

Parameters value types

System parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 U8 0 0 2 0 – Disabled Sleep Settings
1 – GPS Sleep
2 – Deep Sleep
200 U8 1 1 3000 - Sleep Timeout
1001 U8 0 0 1 0 - 10V Analog Input value range
1 – 30V
1002 U8 1 0 3 0 - ignition Stop Detection Source
1 - Msensor
2 - GPS
3 - ignition + Msensor
1003 U8 0 0 1 0 - Disabled Static Navigation
1 – Enabled
1004 0 0 2 0 – Power voltage Ignition Source
1 – Digital input 1
2 – Msensor
1005 30000 mV 13000 mV 30000 mV High Voltage Level
1006 13000 mV 0 30000 mV Low Voltage Level
1008 0 0 1 0 - Manual Ignition Detection
1 – Automatic
1009 U8 10 0 65535 Ignition Detection Timeout
1007 U8 60 0 65535 GNSS FIX Timeout for Time Synchronization via NTP
201 U8 0 0 1 0 - Disabled Saving/Sending without time synchronization
1 – Enabled
202 U8 0 0 2 0 – GNSS (all available) Satellite System
1 – GPS
2 – GLONASS

Records parameters

GSM parameters

Data aquisition parameters

Features parameters

I/O parameters

LV-CAN Features

SMS EVENT CONFIGURATION