*** '''YY''' – the status of CAN line: | *** '''YY''' – the status of CAN line: | ||
− | **** '''01''' – CAN connected, but currently module not | + | **** '''00''' – CAN not connected, connection not required |
− | **** '''02''' – CAN not connected, | + | **** '''01''' – CAN connected, but currently module is not receiving data |
+ | **** '''02''' – CAN not connected, requires connection | ||
**** '''03''' – CAN connected | **** '''03''' – CAN connected | ||
** Examples of responses: | ** Examples of responses: | ||
Line 17: | Line 18: | ||
*** '''YY''' – the status of CAN line: | *** '''YY''' – the status of CAN line: | ||
**** '''00''' – CAN connected, but currently module not received data | **** '''00''' – CAN connected, but currently module not received data | ||
− | **** '''01''' – CAN connected, the currently | + | **** '''01''' – CAN connected, the module is currently receiving data |
− | **** '''02''' – CAN not connected, | + | **** '''02''' – CAN not connected, requires connection |
− | **** '''03''' – CAN not connected, not required | + | **** '''03''' – CAN not connected, connection not required |
** Examples of responses: | ** Examples of responses: | ||
*** CAN1:0x03,CAN2:0x02,CAN3:0x03 | *** CAN1:0x03,CAN2:0x02,CAN3:0x03 | ||
*** CAN line flags are empty! | *** CAN line flags are empty! | ||
*** LVCAN not detected | *** LVCAN not detected | ||
+ | |||
+ | * From '''[[FMB150]]''', '''[[FMC150]]''', '''[[FMM150]]''': | ||
+ | **''CAN'''X''':0x'''YY'''[,],'' where: | ||
+ | ***'''X''' – CAN number | ||
+ | *** '''YY''' – the status of CAN line: | ||
+ | ****'''00''' – CAN connected, but currently module not received data | ||
+ | **** '''01''' – CAN connected, the module is currently receiving data | ||
+ | **** '''02''' – CAN not connected, requires connection | ||
+ | **** '''03''' – CAN not connected, connection not required | ||
+ | ** Examples of responses: | ||
+ | *** CAN1:0x03,CAN2:0x02,CAN3:0x03 | ||
+ | *** CAN line flags are empty! |
Latest revision as of 07:40, 11 September 2023
Possible responses:
- From ALL-CAN300:
- CANX:0xYY[,], where:
- X – CAN number
- YY – the status of CAN line:
- 00 – CAN not connected, connection not required
- 01 – CAN connected, but currently module is not receiving data
- 02 – CAN not connected, requires connection
- 03 – CAN connected
- Examples of responses:
- CAN1:0x03,CAN2:0x02,CAN3:0x03
- CAN line flags are empty!
- LVCAN not detected
- CANX:0xYY[,], where:
- From CAN-CONTROL, FMB140:
- CANX:0xYY[,], where:
- X – CAN number
- YY – the status of CAN line:
- 00 – CAN connected, but currently module not received data
- 01 – CAN connected, the module is currently receiving data
- 02 – CAN not connected, requires connection
- 03 – CAN not connected, connection not required
- Examples of responses:
- CAN1:0x03,CAN2:0x02,CAN3:0x03
- CAN line flags are empty!
- LVCAN not detected
- CANX:0xYY[,], where:
- From FMB150, FMC150, FMM150:
- CANX:0xYY[,], where:
- X – CAN number
- YY – the status of CAN line:
- 00 – CAN connected, but currently module not received data
- 01 – CAN connected, the module is currently receiving data
- 02 – CAN not connected, requires connection
- 03 – CAN not connected, connection not required
- Examples of responses:
- CAN1:0x03,CAN2:0x02,CAN3:0x03
- CAN line flags are empty!
- CANX:0xYY[,], where: