|<strong>Is it possible to know how much data has been used with the current data plan? </strong> | |<strong>Is it possible to know how much data has been used with the current data plan? </strong> | ||
|- | |- | ||
− | | In the configurator Status tab | + | | In the configurator Status tab there is the GPRS traffic section, where data usage can be seen. |
Other than this, there is no way to get the data consumption from the device - this information will be available from the network provider. | Other than this, there is no way to get the data consumption from the device - this information will be available from the network provider. | ||
|} | |} | ||
Line 73: | Line 73: | ||
|<strong>Is there a way to implement seat belt detection with a device with only one digital input? </strong> | |<strong>Is there a way to implement seat belt detection with a device with only one digital input? </strong> | ||
|- | |- | ||
− | | There are 2 methods | + | | There are 2 methods that can be followed: |
1. Digital Input: if the device only has 1 Digital input which is mostly used to connect the ignition cable, In this use case - the ignition source can be set to power voltage and the seatbelt sensor can be connected to Digital input with priority - High and Operand "On change". | 1. Digital Input: if the device only has 1 Digital input which is mostly used to connect the ignition cable, In this use case - the ignition source can be set to power voltage and the seatbelt sensor can be connected to Digital input with priority - High and Operand "On change". | ||
Line 180: | Line 180: | ||
|<strong>How to connect the fuel gauge sensor to the Analog input of the FMx and calibrate for accurate results? </strong> | |<strong>How to connect the fuel gauge sensor to the Analog input of the FMx and calibrate for accurate results? </strong> | ||
|- | |- | ||
− | | | + | | Device can measure the fuel level using analog input by matching the voltage coming from the fuel level sensor already mounted in the car, with the fuel level in the tank. |
More information on how the AIN has to be connected and calibrated can be found here: [[Analog Fuel Sensor]] | More information on how the AIN has to be connected and calibrated can be found here: [[Analog Fuel Sensor]] | ||
|} | |} | ||
Line 195: | Line 195: | ||
|- | |- | ||
|Like other devices with a 1-Wire interface, FMC150 also supports a 1-wire protocol (DS1990A) RFID reader. | |Like other devices with a 1-Wire interface, FMC150 also supports a 1-wire protocol (DS1990A) RFID reader. | ||
− | If the reader reads cards with 125 or 128 kHz and transmits this data through 1 wire protocol (DS1990A), | + | If the reader reads cards with 125 or 128 kHz and transmits this data through 1 wire protocol (DS1990A), an integration can be done for FMX150 devices. |
|} | |} | ||
Revision as of 14:50, 23 January 2024
Firmware
How to send SMS command to Teltonika Telematics device? |
There exists a specific structure that commands must adhere to. For instance, to send the SMS command "getinfo," the following guidelines should be observed:
If SMS login and password are set: login pass getinfo If SMS login and password are not set, leave two spaces before the command: getinfo |
Is it possible to delete records from the device memory? |
Records stored in the device's memory can be cleared by clicking the "format" button in the [Status] window. Alternatively, sending the SMS command "sdformat" remotely accomplishes the same result without requiring a physical connection to a computer. |
Is it possible to show battery % of EYE sensors/beacons? |
No, but it is possible to retrieve the battery voltage and estimate the remaining battery life.
More information about it can be found here: How does the battery voltage translate into the percentage of the battery? Both EYE sensors and EYE Beacons can advertise their battery voltage |
What is autoscan and which Teltonika device models support this feature? |
Autoscan is the process of scanning for CANBUS program numbers in the vehicle CANBUS system. Currently, FMB140 and newest external CAN adapters have the Autoscan feature. |
How to access the latest firmware and how to know when the latest firmware has been released? |
The latest firmware release information is passed through the Teltonika newsletter. It is encouraged that you subscribe to this service to get real-time notifications about the releases.
Base firmware for all devices can also be found here: Firmware versions |
How to activate digital output with SMS command? What commands are available? |
To set digital output use the setdigout command. A description of this command can be found here: FMB_setdigout |
What is the difference between Fuel consumed and Fuel consumed (Counted) or Total mileage and Total Mileage (Counted)? |
Fuel consumed is the total fuel consumed by the vehicle since it was manufactured, while fuel consumed (counted) is the fuel consumed by the vehicle since the CAN device was installed.
Total mileage is the total mileage of the vehicle as displayed on the dashboard of the vehicle since it was manufactured, while total mileage (counted) is the mileage of the vehicle from when the CAN device was installed. |
Does FMC125 work with the Iridium Edge use case? |
Yes, Iridium Edge does work with the FMC125 devices - the 03.28.06.Rev.323 firmware has to be used for this solution to work.
More information about the Iridium Edge solution can be found here: Iridium Edge |
Is there a way to encrypt the data that is sent to the server? |
Yes, our devices have TLS encryption capability, which allows us to secure the data using TLS certificates that are uploaded to the device and the server.
More information about TLS encryption can be found here: TLS settings |
Is it possible to know how much data has been used with the current data plan? |
In the configurator Status tab there is the GPRS traffic section, where data usage can be seen.
Other than this, there is no way to get the data consumption from the device - this information will be available from the network provider. |
Is there a way to implement seat belt detection with a device with only one digital input? |
There are 2 methods that can be followed:
1. Digital Input: if the device only has 1 Digital input which is mostly used to connect the ignition cable, In this use case - the ignition source can be set to power voltage and the seatbelt sensor can be connected to Digital input with priority - High and Operand "On change". 2. Analog Input: The seat belt sensor can be connected to Analog Input 1 with priority - high and low-level values (depending on the voltage from the seatbelt, let's say 12 VDC) - 10 VDC and High level - 13 VDC. The idea is to make the voltage fall between low-level and high-level values and generate an event when the voltage enters that range.
IO settings guide: FMC920 I/O settings It is recommended to use FMX130 as the device has a Ground sense option which will be easier to connect and DIN1 can be used for accurate Ignition detection. |
How to get a SIM card IMSI number on my server? |
The IMSI is not available as an IO element, and it will not be sent to the server with records. However, it can be requested by a SMS/GPRS command "getimsi" |
Why does the TAT100 device appear offline on my server? |
The TAT100 always works in Deep-sleep mode, and the open link Timeout is 30sec maximum, so the device does not stay connected to the server - this is done to preserve the battery life and allow the device to work longer. |
Is it possible to send an SMS or command to the TAT100? |
Yes, you can send a command to the TAT100 and it will execute this command once it wakes up. |
When does TAT100 connect to FOTA WEB? |
TAT100 devices do not connect to FOTA Web periodically. It will automatically connect to FOTA Web only on initial startup (when the switch is flipped from OFF to ON position). Connection to FOTA Web should be initiated via the 'web_connect' SMS/GPRS command. This is to preserve battery power. |
Can DSM detect 2 or more events at the same time? |
Yes, it can detect multiple events at the same time. The events are placed in a queue and then reported based on their generation time. |
Which SMS encoding is supported by Teltonika Telematics devices? |
The device received commands encoded in Unicode and any third-party SMS portal should have the support of format SMS Default Alphabet while initiating communication with the Teltonika device. FMC devices support SMS Default Alphabet, also known as GSM-7, encoding only - this encoding standard should be configured at the sending device/application. |
Software
When opening the configurator, a .NET error is shown. I tried installing .NET 7.0, but the error remained. How can this be solved? |
New Configurators use the newer .NET version - please make sure the correct version is installed and remove other (unused) .NET versions – more information can be found here: .NET Runtime for Desktop installation
Note #1: The Ways to determine the required version section is especially important here. It will help you decide which version you should choose. Note #2: x86 is recommended even with Microsoft Windows 64-bit Operating System. |
What is FOTA Web and how is it useful? Can you see the device's real-time location using this system? |
FOTA Web is simply a device management platform that is used to assign files to the device remotely, such as firmware, configuration files, etc.
FOTA Web is not a tracking platform and does not report the device's real-time location.
|
How to use the device transfer feature in FOTA Web? |
Device transfer is a feature in FOTA Web that allows clients to directly move devices amongst their accounts without the need to involve Teltonika.
More information about this feature can be found here: Device transfer |
How do I update configurations remotely via Teltonika FOTA Web? |
Kindly use the FOTA Web to remotely update configurations to units as explained here: FOTA Web
Steps are: 1. Upload the configuration file in FOTA Web under the files tab. 2. Head over to the devices tab then select the devices to receive the configuration. 3. Click on Create Task and choose Update Configuration on the drop-down then below it, choose the uploaded file, then click on Create Task. The task will be executed the next time the device connects to FOTA Web or you can force it to connect immediately by sending a command web_connect, or by forcing a hard restart of the unit by unplugging the power and the internal battery then plugging it back on - then the task will be executed immediately. |
Hardware
What are the SIM card requirements for use with Teltonika Telematics devices? |
Different Teltonika Telematics devices support Mini SIM, Micro SIM, and Nano SIM sized SIM cards. To know the exact SIM card supported by Your device, please check the General Description Wiki page for Your device.
|
How to connect the fuel gauge sensor to the Analog input of the FMx and calibrate for accurate results? |
Device can measure the fuel level using analog input by matching the voltage coming from the fuel level sensor already mounted in the car, with the fuel level in the tank.
More information on how the AIN has to be connected and calibrated can be found here: Analog Fuel Sensor |
Where the connection schemes for CAN-CONTROL adapter can be found? |
Please create a Helpdesk ticket for our support team and specify the vehicle that the connection scheme is needed for.
The whole supported vehicle list for CAN-CONTROL adapter can be found here: CAN adapter supported vehicles |
Do all RFID cards with 125 or 128kHz frequency work with FMC150 ? What about a 13.56 MHz NFC or RFID device? |
Like other devices with a 1-Wire interface, FMC150 also supports a 1-wire protocol (DS1990A) RFID reader.
If the reader reads cards with 125 or 128 kHz and transmits this data through 1 wire protocol (DS1990A), an integration can be done for FMX150 devices. |
How many batteries does TAT1XY use? |
TAT1XY uses 1 battery, which consists of 2 (7.2V variant) or 3 (10.8V variant) cells. Currently, manufactured TAT devices use 3-cell batteries. |
What is the battery life of TAT1XY? |
TAT1XX can send approximately 1000 records, this may differ depending on the environment, coverage, Temperature, and device mounting, |
Protocols
Where information on how to parse messages from Teltonika Telematics devices can be found? |
Teltonika data sending protocol Codec 8 and Codec 8Extended description with examples:
TCP/UDP listener and AVL parser with source code that could be used as a template for implementation of Teltonika protocols. The whole pack can be downloaded from here: |
In documentation it states that the Beacon data will be sent via AVL ID 385, but data from FMB140 is being sent with AVL ID:548. |
When the simple mode is selected beacon parsing is done automatically so AVL ID:385 is used
When advanced beacon mode is selected, beacon data capturing can be configured manually and to distinguish simple and advanced functionalities a different ID is used - AVL ID 548. For advanced beacon configuration documentation, you can find it here: Advanced Beacon Capturing Configuration |
I have implemented Codec8 Extended protocol. Communication is working correctly, IMEI and AVL packets are working fine, but the unit sends 0xFF instead of AVL packets sometimes. Is there any use of this packet and is it necessary to send some data as a response back? |
It seems that You have enabled the Network Ping Timeout feature.
What Network Ping Timeout does is it sends an empty packet (0xFF) to the server to make sure that the operator does not close a link between the device and the server. If you don't want to receive 0xFF packets anymore you can set Network Ping Timeout to 0 seconds. |
Configuration
I have successfully paired the Teltonika Eye sensor to the fleet management device and I can see the data on the I/O tab but the data is not sent to my platform, what could be the issue? |
For the data to be sent to the platform, the I/O needs to have a priority of ‘Low’, ‘High’, or ‘Panic’ so that the data can be sent with periodical data to the platform.
I/O Settings wiki page - FMB125 I/O settings |
Why device does not detect the ignition? |
Please check which ignition source have you chosen and configure the device according to Your use case.
More information about the Ignition sources can be found here: Ignition source |
When testing an OBD device, alarm of the vehicle is triggered when it is parked. What could cause this? |
This usually occurs when the device tries making OBD requests while the vehicle has no ignition and is locked. This can happen due to improper configuration, so make sure that the OBD device properly detects the ignition of the vehicle, when the ignition is actually ON.
More information about the Ignition sources can be found here: Ignition source |
How to calculate how much data device is going to consume according to configuration? |
The total number of data consumption bytes depends on parameters, features and also the frequency of data sending configured in Data Acquisition.
By counting the bytes of each enabled parameter, the size of one packet can be calculated. Once the frequency or amount of packets sent is known only multiplication needs to be done: Packet Size X Amount of packets Important note: Network operators round the packets into larger chunks, e.g.: if device sends 800 Bytes of data, operators can round it to 1 kB (1024 Bytes). You can find the size of each IO in the below link: |