Difference between revisions of "ECAN01"
From Wiki Knowledge Base | Teltonika GPS
Line 180: | Line 180: | ||
|} | |} | ||
− | == | + | ==Additional information== |
+ | |||
[https://teltonika-gps.com/product/ecan01/ ECAN01 Teltonika] | [https://teltonika-gps.com/product/ecan01/ ECAN01 Teltonika] | ||
+ | |||
+ | {{{EOL|For EOL policy please refer to link [https://teltonika-gps.com/support/eol-products here].}}} | ||
[[Category:CAN Trackers & Adapters]] | [[Category:CAN Trackers & Adapters]] |
Latest revision as of 07:41, 8 October 2024
Main Page > CAN Trackers & Adapters > ECAN01This Product is started transition to EOL.
- Last Order date: 20 October 2023
- End of Production date: 22 January 2024
- End of Support date: 22 July 2024
ECAN01 is contactless adapter used to read vehicle CAN Bus data. ECAN01 adapter should be used in combination with:
It reads can-bus data through the isolation of wires without damaging them and forwards signals to the tracking device.
Features
- ECAN01 collects vehicle data from CAN bus without damaging the wires
- Powered from an on-board power source
- Reads the signals through the isolation of CAN bus wires
- Easy to install and operate
Technical features
PARAMETER | VALUE | ||||
---|---|---|---|---|---|
Minimum | Typical | Typical | Maximum | Unit | |
Supply Voltage | |||||
Supply Voltage (Recommended Operating Conditions) | +10 | +12 | +24 | +30 | V |
Current Consumption | |||||
Working Mode | 6.9 | mA | |||
Sleep Mode | 1.2 | mA | |||
Operating Temperature | |||||
Operating Temperature | -25 | +85 | °C | ||
Protection | |||||
Internal resettable fuse (max 33 V) | 750 | mA |
- Dimensions 39.8 x 18 x 16.7 mm
- CAN-BUS speeds up to 500 kb/s
- Fuse is protecting devices from high current peaks. If the voltage exceeds 33V (i.e. 35V) then protection diode stabilizes device voltage to 33V and the current value will increase accordingly.
Pinout
PIN NUMBER | PIN NAME |
DESCRIPTION |
---|---|---|
1 | CAN L | (Blue) Connect to CAN L input of CAN BUS converter |
2 | CAN H | (White/Blue) Connect to CAN H input of CAN BUS converter |
3 | VCC | (RED) Power supply (10-30) V DC (+) |
4 | GND (-) | (Black) Ground wire (10-30) V DC (-) |
Wiring scheme
Set up ECAN01
- Gently open ECAN01 cover using plastic pry tool from both sides
- Insert CAN wires as shown in figure 2. Please make sure that correct slots are used (CAN High/CAN Low)
- Gently close the device.
- Device is ready-to-use.
Certification & Approvals
Memberships
Nomenclature, classification codes
FAQ
- How to install SIMPLE-CAN with LV-CAN200/ALL-CAN300 using:
- FMB110
- FMB120
- FMB122
- FMB125
- FMB110
- FMA120
- FMB630
- FMB640
- FM6300
- FM6320
- FM36M1
- FM3622
- FM3612
Product Change Notifications
ECAN01 Product Change Notifications
YouTube
Teltonika CAN adapters Part 1: Introduction
Teltonika CAN adapters Part 2: Installation
Promotional Material
Downloads
Manual & Documentation
ECAN01 Datasheet (EN) | (Updated on: 2023-07-03) |
ECAN01 vs ECAN02 flyer | (Updated on: 2023-06-22) |
Additional information
For EOL policy please refer to link here.