How to insert Micro-SIM card

  1. Gently remove FMB96X cover using plastic pry tool from both sides.
  2. Insert Micro-SIM card as shown with PIN request disabled or read Security info how to enter it later in Configurator. Make sure that Micro-SIM card cut-off corner is pointing forward to slot.
  3. Attach device cover back.
  4. Device is ready to be connected.


  1. Gently remove FMB96X cover using plastic pry tool from both sides.
  2. Insert Micro-SIM card as shown with PIN request disabled or read Security info how to enter it later in Configurator. Make sure that Micro-SIM card cut-off corner is pointing forward to slot.
  3. Connect the battery as shown on device. Position the battery in place where it does not obstruct other components.
  4. Attach device cover back. Device is ready to be connected.


FMB964 SIM Battery 1.pngFMB964 sim battery insert 2.pngFMB964 sim battery insert 3.pngFMB964 sim battery insert 4.png


Alert.png
Note: Micro-SIM card insertion/removal must be performed when device is powered off – external voltage and battery are disconnected. Otherwise Micro-SIM card might be damaged or device will not detect it.


How to install FMB96X drivers (Windows)

1. Please download COM port drivers from Teltonika here

2. Extract and run TeltonikaCOMDriver.exe. This driver is used to control FMB96X device when it is connected to the computer.

3. Click Next in driver installation window.

4. In the following window click Install button.

5. Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup. You are now ready to use the device on your computer.

Configuration (Windows)

.NET requirements
Operating system MS .NET Framework version Version Links
Windows Vista
Windows 7
Windows 8.1
Windows 10
MS .NET Framework 4.6.2 32 and 64 bit https://www.microsoft.com/en-us/download/confirmation.aspx?id=53344

http://avl1.teltonika.lt/downloads/software/Framework/.NET%20Framework%204.6.2/NDP462-KB3151800-x86-x64-AllOS-ENU.exe

At first FMB96X device will have default factory settings set. These settings should be changed according to the user's needs.
FMB96X module is designed to acquire records and send them to the server. Records contain GNSS data and I/O information. Module uses GNSS receiver to acquire GNSS data and is powered with three data acquiring methods: time-based, distance-based and angle-based. Note, that if FMB96X loses connection to GNSS satellites, it continues to make records, however coordinate in these records remains the same (last known coordinate). All data is stored in flash memory and later can be sent via GPRS.
FMB96X configuration is performed via FMB96X Configurator program. Contact sales manager to get the latest FMB96X Configurator version or download from here. FMB96X configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework.

FMB920 configurator.png

Module configuration can be performed over USB cable or using a Bluetooth connection. Configuration process begins by starting FMB96X Configurator software and then connecting to FMB96X device by selecting active device from startup Configurator screen. Current set parameters will be loaded from device automatically. FMB96X has one user editable profile, which can be loaded and saved to the device. After any modification of configuration the changes need to be saved to FMB96X device using Save to device button.
Main buttons offer following functionality:

  • Load from device – loads configuration from device.
  • Save to device – saves configuration to device.
  • Load from file – loads configuration from file.
  • Save to file – saves configuration to file.
  • Update firmware – updates firmware on device.
  • Reset configuration – sets device configuration to default.

More details on using the Configurator can be found in the product manual.


Mounting recommendations

  • Connecting wires
    • Wires should be fastened to the other wires or non-moving parts. Try to avoid heat emitting and moving objects near the wires.
    • The connections should not be seen very clearly. If factory isolation was removed while connecting wires, it should be applied again.
    • If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied.
    • Wires cannot be connected to the board computers or control units.
  • Connecting power source
    • Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the car model, this may happen in 5 to 30 minutes period.
    • When the module is connected, measure the voltage again to make sure it did not decrease.
    • It is recommended to connect to the main power cable in the fuse box.
    • 3 A, 125 V external fuse shall be used.
  • Connecting ignition wire
    • Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
    • Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
    • Check if power is still available when you turn off any of vehicles devices.
    • Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen.
  • Connecting ground wire
    • Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
    • If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
    • For better contact scrub paint from the spot where loop is going to be connected.


Alert.png
PAY ATTENTION! Connecting the power supply must be carried out in a very low impedance point of on-board vehicle network. These points in the car are the battery terminals. Therefore, we recommend connecting the power of FMB96X (GND and POWER wires) directly to the battery terminals. Another valid option is to connect the wires to the main POWER cable inside the fuse box (if there is none, then to the power supply where the fuses of vehicle’s computer are), GND wire must be connected in a special point, designed to connect GND vehicle computer. Connecting the GND at an arbitrary point to the mass of the car is unacceptable, as static and dynamic potentials on the line GND will be unpredictable, which can lead to unstable FMB96X operation and even its failure.

Safety information

This chapter contains information on how to operate FMB96YX safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!

  • The device uses SELV limited power source. The nominal voltage is 12 V DC. The allowed range of voltage is 6 V...30 V DC.
  • To avoid mechanical damage, it is advised to transport the FMB96YX device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible, which show the status of operation the device is in.
  • When connecting the connection (1x5) cables to the vehicle, the appropriate jumpers of the power supply of the vehicle should be disconnected.
  • Before dismounting the device from the vehicle, the 1x5 connection must be disconnected.
  • The device is designed to be mounted in a zone of limited access, which is inaccessible for the operator. All related devices must meet the requirements of standard EN 60950-1.
  • The device FMB96YX is not designed as a navigational device for boats.

Precautions

Bw nb.png Do not disassemble the device. If the device is damaged, the power supply cables are not isolated or the isolation is damaged, DO NOT touch the device before unplugging the power supply.
Bw nb.png All wireless data transferring devices produce interference that may affect other devices which are placed nearby.
Bw key.png The device must be connected only by qualified personnel.
Bw tick.png The device must be firmly fastened in a predefined location.
Bw tick.png The programming must be performed using a PC with autonomic power supply.
Bw humidity.png The device is susceptible to water and humidity.
Bw ecute.png Installation and/or handling during a lightning storm is prohibited.