Changes

Line 45: Line 45:  
'''CONNECTING WIRES'''
 
'''CONNECTING WIRES'''
   −
Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.<br />
+
* Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.<br />
There should be no exposed wires. If factory isolation was removed while connecting wires, the isolation material should be applied.<br />
+
* There should be no exposed wires. If factory isolation was removed while connecting wires, the isolation material should be applied.<br />
If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be <br />applied and the wires should not be loose.<br />
+
* If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be <br />applied and the wires should not be loose.<br />
Wires cannot be connected to the board computers or control units.<br />
+
* Wires cannot be connected to the board computers or control units.<br />
    
'''CONNECTING POWER SOURCE'''
 
'''CONNECTING POWER SOURCE'''
   −
Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on car, this may happen in 5 to 30 minutes period.<br />
+
* Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on car, this may happen in 5 to 30 minutes period.<br />
When module is connected, measure voltage again to make sure it did not decrease.<br />
+
* When module is connected, measure voltage again to make sure it did not decrease.<br />
It is recommended to connect to the main power cable in the fuse box.<br />
+
* It is recommended to connect to the main power cable in the fuse box.<br />
3 A, 125 V external fuse shall be used.<br />
+
* 3 A, 125 V external fuse shall be used.<br />
    
'''CONNECTING GROUND WIRE'''
 
'''CONNECTING GROUND WIRE'''
   −
Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.<br />
+
* Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.<br />
If the wire is fixed with the bolt, the loop must be connected to the end of the wire.<br />
+
* If the wire is fixed with the bolt, the loop must be connected to the end of the wire.<br />
For better contact scrub paint from the spot where loop is going to be connected.<br />
+
* For better contact scrub paint from the spot where loop is going to be connected.<br />
    
[[Category:FTC921]]
 