Difference between revisions of "FMM640 I/O settings"

From Wiki Knowledge Base | Teltonika GPS
m (Protected "FMM640 I/O settings" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
(One intermediate revision by one other user not shown)
Line 2: Line 2:
  
 
{{Template:FMM640 Operands|model=FMM640}}
 
{{Template:FMM640 Operands|model=FMM640}}
 
{{Template:FMM640 Avg Const|model=FMM640}}
 
  
 
[[Category:FMM640 Configuration]]
 
[[Category:FMM640 Configuration]]

Revision as of 15:14, 22 August 2019

Main Page > EOL Products > FMM640 > FMM640 Configuration > FMM640 I/O settings

When no I/O element is enabled, AVL packet comes with GNSS information only. After enabling I/O element(s) AVL packet contains current value(s) of enabled I/O element(s) along with GNSS information. If the device is connected to configurator all current I/O values are displayed in Current Value column. Priority field allows enabling I/O elements and setting them a priority so they are added to the data packet, which is sent to the server. By default 10 I/O elements with low priority are enabled: Ignition, Movement, Data Mode, GSM Signal, Sleep Mode, GNSS Status, GNSS PDOP, GNSS HDOP, External Voltage and Speed. Priority level (AVL packet priority) can be Low, High or Panic. All records made by FMM640 are regular, and regular packets are sent as low priority records. When Low priority event is triggered, FMM640 makes an additional record with an indication that the event was caused by an I/O element change (depending on Operand configuration). When High priority is selected, module makes an additional record with high priority flag and sends event packet immediately to the server using GPRS. Panic priority triggers same actions as High priority, but if GPRS fails, it sends an AVL packet using SMS data if SMS data sending is enabled and the number is provided in SMS/Call Settings. High and Low levels define I/O value range. If I/O value enters or exits this range, FMM640 generates an event. Operand parameter defines when to generate event: On Exit, On Entrance, On Both, On Hysteresis or On Delta Change. When Event Only is selected, I/O element status value will be appended only to eventual records, otherwise I/O element status value will appear in each AVL record.

Operands

Operand On Exit

Record is generated when input value leaves a range between low and high level limits.

Fmb120 on exit.png

Operand On Entrance


Record is generated when input value enters a range between low and high level limits.

Fmb120 on entrance.png

Operand On Both


Record is generated by both On Exit and On Entrance operands' logic at same time.

Fmb120 on both.png

Operand Monitoring


No event at all. Values are recorded only when other triggers worked.

Fmb120 operand monitoring.png

Operand On Hysteresis


Record is generated when input value crosses the high limit value from below the low limit value or vice versa.

Fmb120 on hysteresis.png

Operand On Change


Record is generated when input value changes.

Fmb120 on change.png

Operand On Delta Change


Record is generated when input value changes and the absolute change becomes equal to or higher than the limit value.

Fmb120 on delta change.png