{| class="wikitable" style="border-style: solid; border-width: 0px;"
 +
| style="width: auto; text-align: left; background: #F6F6FB;" |'''(!) Only works with FMx640 and FMC650'''
 +
|}
  
 
==DSM connection scheme==
 
==DSM connection scheme==
[[File:DSM connection scheme.jpg|center|
 
  
 +
'''Please note that camera must be connected to ignition source, in other way camera will drain battery.'''
  
 +
[[File:DSM connection scheme.jpg|800px]]
  
  
'''NOTE: FMX640 device also needs SD Card to be inserted.''' ]]
+
'''Camera connection through a relay'''
  
 +
If you need to receive additional data from the DSM when the ignition is off but the key is inserted and turned to ACC postition, you can do it by connecting the camera to a power source using a relay in order to control the power supply by turning on/off the camera. To find information on how to configure DOUT, please visit [[FMB setdigout|FMB DOUT]].
  
'''NOTE: FMX640 device also needs SD Card to be inserted.'''
+
[[File:DSM connection.jpg|800px]]
  
==PC Calibration==
+
'''Two cameras FMC650 Installation with Ignition Source'''. To connect the two cameras to the FMC650 device, you have to make sure to connect 4 PIN's of the camera to the PIN's of your device correctly.  
[[File:DSM_Calib.png | right | 320x320px]]
 
Driver Setup (ONLY SUPPORTS WINDOWS OS)
 
* NOTE: Before you connect or start calibration, please install RNDIS driver first.
 
Calibration Setup
 
* Access DSM Calibration page via PC
 
** Connect DSM to PC using Micro USB cable with 5 pins.
 
** Power on DSM. If you hear repeated beep sound, this means DSM is properly connected to computer.
 
** Activate the browser and enter into http://20.0.0.1:18087/ to access DSM calibration page. Google Chrome is recommended.
 
** If you see the page below, please select language you want and sign in using following information
 
  ‐ ID: admin ‐ Password: 1234
 
  
==== Calibration ====
+
'''NOTE:''' Two cameras must be connected to the ignition source or another source, where then you turn off ignition camera will turn off in another case camera will drain the battery if you connect directly.
* Select Speed Type
 
** GPS Speed setting - GPS antenna is embedded on DSM. If GPS work correctly, detected is shown. If GPS doesn’t work for 5 mins, Fail is shown.
 
  
[[File:DSM Calib2.png|400px|center-left]] [[File:DSM Calib3.png|400px|center-right]]
+
[[File:688548 DualCam and DSM with FMC650.jpg]]
  
====  CAN Speed setting ====
+
'''Two cameras FMC650 Installation with Relay'''. If you need to receive additional data from the Two cameras or one of them when the ignition is off, you can also connect the camera to a power source using the relay, to control the power supply by turning on/off the camera. To find information on how to configure DOUT, please visit [[FMB setdigout|FMB DOUT]].
*DSM can get speed through CAN as well.
 
*DSM only recognizes encrypted CAN data from our Database site; http://info.mdas.co.kr
 
  
Please download can file from the DB and upload to system.
+
[[File:2 cameras dout.JPG|frameless|928x928px]]
  
[[File:Mdas1.0.png|frameless|450x450px]]
 
  
==== Verify Speed Signal ====
+
'''NOTE: FMX640 device also needs SD Card to be inserted. The FMX650 can be used with the feature without an SD card.'''
You can check the speed data is coming correct by test drive.
 
  
If there is a deviation, please use the following correction method.
+
Using the above information in regards to connection, please follow the below steps:
  
Please click the “Correction” button when you drive at 40km/h (24mph). Then, DSM will set new speed automatically.
+
# Insert Micro SD Card into the DSM camera main block.
[[File:Mdas1.1.png|450x450px]]
+
# Connect DSM camera to the main block
 +
# Connect main block with power and ground wires either to the vehicles relay (see picture above) or power supply.
 +
# The RX and TX cables from the main block have to be connected through the RJ-45 cable to the FMX640 device. '''Pin can be 3/4 or 5/6 different RJ45 cable modification'''
 +
# Connect FMX640 device with PWR and Ground to power supply or vehicle's relay (see picture above).  
 +
# Connect DOUT (1,2,3,4) to relay in order to control immobilizer and DSM camera state.  
 +
# Continue in configurator in order to set up the DSM camera [https://wiki.teltonika-gps.com/view/DSM_Configuration here].
  
==== Camera Setting ====
 
  
# Place your face inside the guide box. The face box should fit inside the guide box to proceed to next step.
 
# Wait 3 seconds to complete and save camera setting.
 
# When the setting is complete, the page will change like below and the unit will make multiple beeps.
 
 
[[File:Auto Camera Setting img.jpg|450x450px]]
 
 
==== DSM Setup ====
 
The camera can also be configured through its configuration, main settings that which can be seen are pointed below:
 
 
[[File:Dms1.03.png]]
 
 
Configurable parameters:
 
 
*ON/OFF: Enable Drowsiness, Distraction, Phone, Smoking, Yawning.
 
*Sound Type: Check the warning sound and select the one you prefer. Press Play button to test Warning Alarm Sound.
 
*Vibrator: Enable vitration function. (On / Off)
 
*Sensitivity: Set the sensitivity on a scale of 1 to 3. As the level gets higher, it gets more sensitive. Yawning warning will generate when yawning for 2 seconds.
 
*Activation Speed:
 
# You can set up activation speed by DSM alert respectively.
 
# Set the Activation Speed ( 15 ~ 60Km/h ≒ 10 ~ 40mph). The functions will be acticvated when the vehicle is faster than this speed.
 
# If you select Others, you can input the activation speed in the below box. Note that the input range is between 5Km and 100km.
 
* DIP switch on unit: Enable DIP switch on DSM’s unit.
 
* Sound Level: Control the warning sound level on a scale of 1 to 4.
 
* Test Mode : If you want to test DSM at any speed, please select “ON” ⑨ Time-out Feature: Select if apply below time-out logic. (On / Off) * Time-out feature: An event and chime will be fired when ‘First Trigger Count’ number of triggers happen within ‘First Trigger Interval’. After the first event and chine, additional events’chimes up to ‘Max Trigger Count’ will be fired as long as they happen within ‘Max Trigger Interval’. When ‘First Trigger Interval’ or ‘Max Trigger Interval’ expire, the trigger count it reset to 0.
 
 
[[Category:DSM]]
 
[[Category:DSM]]

Latest revision as of 12:26, 29 July 2024

Main Page > Video Solutions > DSM > DSM First Start
(!) Only works with FMx640 and FMC650

DSM connection scheme

Please note that camera must be connected to ignition source, in other way camera will drain battery.

DSM connection scheme.jpg


Camera connection through a relay

If you need to receive additional data from the DSM when the ignition is off but the key is inserted and turned to ACC postition, you can do it by connecting the camera to a power source using a relay in order to control the power supply by turning on/off the camera. To find information on how to configure DOUT, please visit FMB DOUT.

DSM connection.jpg

Two cameras FMC650 Installation with Ignition Source. To connect the two cameras to the FMC650 device, you have to make sure to connect 4 PIN's of the camera to the PIN's of your device correctly.

NOTE: Two cameras must be connected to the ignition source or another source, where then you turn off ignition camera will turn off in another case camera will drain the battery if you connect directly.

688548 DualCam and DSM with FMC650.jpg

Two cameras FMC650 Installation with Relay. If you need to receive additional data from the Two cameras or one of them when the ignition is off, you can also connect the camera to a power source using the relay, to control the power supply by turning on/off the camera. To find information on how to configure DOUT, please visit FMB DOUT.

2 cameras dout.JPG


NOTE: FMX640 device also needs SD Card to be inserted. The FMX650 can be used with the feature without an SD card.

Using the above information in regards to connection, please follow the below steps:

  1. Insert Micro SD Card into the DSM camera main block.
  2. Connect DSM camera to the main block
  3. Connect main block with power and ground wires either to the vehicles relay (see picture above) or power supply.
  4. The RX and TX cables from the main block have to be connected through the RJ-45 cable to the FMX640 device. Pin can be 3/4 or 5/6 different RJ45 cable modification
  5. Connect FMX640 device with PWR and Ground to power supply or vehicle's relay (see picture above).
  6. Connect DOUT (1,2,3,4) to relay in order to control immobilizer and DSM camera state.
  7. Continue in configurator in order to set up the DSM camera here.