Difference between revisions of "DSM First Start"

From Wiki Knowledge Base | Teltonika GPS
Line 2: Line 2:
  
 
==DSM connection scheme==
 
==DSM connection scheme==
 +
 +
'''Please note that camera must be connected to ignition source, in other way camera will drain battery'''
 
[[File:DSM connection scheme.jpg|center|
 
[[File:DSM connection scheme.jpg|center|
  
Line 10: Line 12:
  
  
'''NOTE: FMX640 device also needs SD Card to be inserted.'''  
+
'''NOTE: FMX640 device also needs SD Card to be inserted.'''
  
 
==PC Calibration==
 
==PC Calibration==

Revision as of 23:27, 10 February 2023

Main Page > Video Solutions > DSM > DSM First Start

DSM connection scheme

Please note that camera must be connected to ignition source, in other way camera will drain battery

NOTE: FMX640 device also needs SD Card to be inserted.


NOTE: FMX640 device also needs SD Card to be inserted.

PC Calibration

DSM Calib.png

Driver Setup (ONLY SUPPORTS WINDOWS OS)

  • NOTE: Before you connect or start calibration, please install RNDIS driver first.

Calibration Setup

  • Access DSM Calibration page via PC
    • Connect DSM to PC using USB Tipe-C cable with 5 pins.
    • Power on DSM. If you hear repeated beep sound, this means DSM is properly connected to computer.
    • Activate the browser and enter into http://20.0.0.1:18087/ to access DSM calibration page. Google Chrome is recommended.
    • If you see the page below, please select language you want and sign in using following information
 ‐ ID: admin ‐ Password: 1234

Calibration

  • Select Speed Type
    • GPS Speed setting - GPS antenna is embedded on DSM. If GPS work correctly, detected is shown. If GPS doesn’t work for 5 mins, Fail is shown.

center-left center-right

CAN Speed setting

  • DSM can get speed through CAN as well.
  • DSM only recognizes encrypted CAN data from our Database site; http://info.mdas.co.kr

Please download can file from the DB and upload to system.

Mdas1.0.png

Verify Speed Signal

You can check the speed data is coming correct by test drive.

If there is a deviation, please use the following correction method.

Please click the “Correction” button when you drive at 40km/h (24mph). Then, DSM will set new speed automatically. Mdas1.1.png

Camera Setting

  1. Place your face inside the guide box. The face box should fit inside the guide box to proceed to next step.
  2. Wait 3 seconds to complete and save camera setting.
  3. When the setting is complete, the page will change like below and the unit will make multiple beeps.

Auto Camera Setting img.jpg

DSM Setup

The camera can also be configured through its configuration, main settings that which can be seen are pointed below:

Dms1.03.png

Configurable parameters:

  • ON/OFF: Enable Drowsiness, Distraction, Phone, Smoking, Yawning.
  • Sound Type: Check the warning sound and select the one you prefer. Press Play button to test Warning Alarm Sound.
  • Vibrator: Enable vitration function. (On / Off)
  • Sensitivity: Set the sensitivity on a scale of 1 to 3. As the level gets higher, it gets more sensitive. Yawning warning will generate when yawning for 2 seconds.
  • Activation Speed:
  1. You can set up activation speed by DSM alert respectively.
  2. Set the Activation Speed ( 15 ~ 60Km/h ≒ 10 ~ 40mph). The functions will be acticvated when the vehicle is faster than this speed.
  3. If you select Others, you can input the activation speed in the below box. Note that the input range is between 5Km and 100km.
  • DIP switch on unit: Enable DIP switch on DSM’s unit.
  • Sound Level: Control the warning sound level on a scale of 1 to 4.
  • Test Mode : If you want to test DSM at any speed, please select “ON” ⑨ Time-out Feature: Select if apply below time-out logic. (On / Off) * Time-out feature: An event and chime will be fired when ‘First Trigger Count’ number of triggers happen within ‘First Trigger Interval’. After the first event and chine, additional events’chimes up to ‘Max Trigger Count’ will be fired as long as they happen within ‘Max Trigger Interval’. When ‘First Trigger Interval’ or ‘Max Trigger Interval’ expire, the trigger count it reset to 0.