Difference between revisions of "ECAN01"

From Wiki Knowledge Base | Teltonika GPS
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
[[File:ECAN01_TOP.png|right|400px]]
 
[[File:ECAN01_TOP.png|right|400px]]
 
[[File:ECAN01_BOTTOM.png|right|400px]]
 
[[File:ECAN01_BOTTOM.png|right|400px]]
 +
'''This Product is started transition to EOL.'''
 +
* '''Last Order date: 20 October 2023'''
 +
* '''End of Production date: 22 January 2024'''
 +
* '''End of Support date: 22 July 2024'''
 +
 
[https://teltonika-gps.com/product/ECAN01/ ECAN01] is contactless adapter used to read vehicle [https://en.wikipedia.org/wiki/CAN_bus CAN Bus] data. [https://teltonika-gps.com/product/ECAN01/ ECAN01] adapter should be used in combination with:
 
[https://teltonika-gps.com/product/ECAN01/ ECAN01] is contactless adapter used to read vehicle [https://en.wikipedia.org/wiki/CAN_bus CAN Bus] data. [https://teltonika-gps.com/product/ECAN01/ ECAN01] adapter should be used in combination with:
  
Line 175: Line 180:
 
|}
 
|}
  
==External Links==
+
==Additional information==
 +
 
 
[https://teltonika-gps.com/product/ecan01/ ECAN01 Teltonika]
 
[https://teltonika-gps.com/product/ecan01/ ECAN01 Teltonika]
 +
 +
{{{EOL|For EOL policy please refer to link [https://teltonika-gps.com/support/eol-products here].}}}
  
 
[[Category:CAN Trackers & Adapters]]
 
[[Category:CAN Trackers & Adapters]]

Latest revision as of 07:41, 8 October 2024

Main Page > CAN Trackers & Adapters > ECAN01
ECAN01 TOP.png
ECAN01 BOTTOM.png

This Product is started transition to EOL.

  • Last Order date: 20 October 2023
  • End of Production date: 22 January 2024
  • End of Support date: 22 July 2024

ECAN01 is contactless adapter used to read vehicle CAN Bus data. ECAN01 adapter should be used in combination with:

It reads can-bus data through the isolation of wires without damaging them and forwards signals to the tracking device.

Features

  • ECAN01 collects vehicle data from CAN bus without damaging the wires
  • Powered from an on-board power source
  • Reads the signals through the isolation of CAN bus wires
  • Easy to install and operate

Technical features

PARAMETER VALUE
Minimum Typical Typical Maximum Unit
Supply Voltage
Supply Voltage (Recommended Operating Conditions) +10 +12 +24 +30 V
Current Consumption
Working Mode 6.9 mA
Sleep Mode 1.2 mA
Operating Temperature
Operating Temperature -25 +85 °C
Protection
Internal resettable fuse (max 33 V) 750 mA
  • Dimensions 39.8 x 18 x 16.7 mm
  • CAN-BUS speeds up to 500 kb/s
  • Fuse is protecting devices from high current peaks. If the voltage exceeds 33V (i.e. 35V) then protection diode stabilizes device voltage to 33V and the current value will increase accordingly.

Pinout

PIN NUMBER PIN NAME

DESCRIPTION

1 CAN L (Blue) Connect to CAN L input of CAN BUS converter
2 CAN H (White/Blue) Connect to CAN H input of CAN BUS converter
3 VCC (RED) Power supply (10-30) V DC (+)
4 GND (-) (Black) Ground wire (10-30) V DC (-)
ECAN01 pinout-01.png

Wiring scheme

ECAN01 wiring scheme.png

Set up ECAN01

  1. Gently open ECAN01 cover using plastic pry tool from both sides
  2. Insert CAN wires as shown in figure 2. Please make sure that correct slots are used (CAN High/CAN Low)
  3. Gently close the device.
  4. Device is ready-to-use.

Gently open ECAN01.pngInsert CAN wires to ECAN01.pngClose ECAN01 cover.pngECAN01 is ready to use.png

Certification & Approvals

Memberships

Nomenclature, classification codes

FAQ

Product Change Notifications

ECAN01 Product Change Notifications

YouTube

Teltonika CAN adapters Part 1: Introduction
Teltonika CAN adapters Part 2: Installation

Promotional Material

ECAN01 Promotional Material

Downloads

Manual & Documentation

Pdf icon.png ECAN01 Datasheet (EN) (Updated on: 2023-07-03)
Pdf icon.png ECAN01 vs ECAN02 flyer (Updated on: 2023-06-22)

Additional information

ECAN01 Teltonika

For EOL policy please refer to link here.