Difference between revisions of "TSM232"
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
[[File:TSM232 2019-11-20.1.png|right|350px]] | [[File:TSM232 2019-11-20.1.png|right|350px]] | ||
+ | |||
+ | |||
+ | '''<p style="color:red;">This Product is started transition to EOL and will be discontinued by 2022.01.01:</p>''' | ||
+ | |||
+ | * '''Last Order date: 2021.10.01''' | ||
+ | * '''End Of Production date: 2022.01.01''' | ||
+ | * '''End of Bug-Fixing date: 2023.07.01''' | ||
+ | * '''End Of Support date: 2024.01.01''' | ||
Teltonika TSM232 is the Iridium SATELLITE terminal with a backup battery. The full solution combines Teltonika TSM232 with Teltonika FM63XY, FMB630, or FMB640 connected via RS232. This solution allows transferring data to a server via the Iridium satellite network when other terrestrial networks are unavailable. High capacity internal Ni-MH battery ensures long autonomous working hours when the main power source is disconnected. Such a solution meets the demand for high-security logistics, marine transport, construction & mining transport, oil/gas industry, public safety, government/defense, and more. | Teltonika TSM232 is the Iridium SATELLITE terminal with a backup battery. The full solution combines Teltonika TSM232 with Teltonika FM63XY, FMB630, or FMB640 connected via RS232. This solution allows transferring data to a server via the Iridium satellite network when other terrestrial networks are unavailable. High capacity internal Ni-MH battery ensures long autonomous working hours when the main power source is disconnected. Such a solution meets the demand for high-security logistics, marine transport, construction & mining transport, oil/gas industry, public safety, government/defense, and more. | ||
Line 9: | Line 17: | ||
*Data transferring via Iridium satellite network when GSM network is unavailable | *Data transferring via Iridium satellite network when GSM network is unavailable | ||
− | *Smart | + | *Smart RS232 communication algorithm |
*One FM63XY/FMB630/FMB640 message size forwarded to TSM232 is only 14bytes | *One FM63XY/FMB630/FMB640 message size forwarded to TSM232 is only 14bytes | ||
*Message contains: Time/Coordinates/Speed/DIN1-4/DOUT1-2/Event ID | *Message contains: Time/Coordinates/Speed/DIN1-4/DOUT1-2/Event ID | ||
Line 174: | Line 182: | ||
==Product Change Notifications== | ==Product Change Notifications== | ||
+ | |||
+ | ===2020.06.29: TSM232 END OF LIFE Announcement=== | ||
+ | The product End of Life (EOL) announcement signifies that a product has entered the final phase of Teltonika Product Life Cycle. Announcement serves as an advance notice of product termination in accordance with Teltonika EOL policy. Nevertheless, there is still enough time for you to order and get support that you need for the products that will be discontinued. Please contact your sales manager for more information. | ||
+ | |||
+ | <br>EOL Plan: | ||
+ | * '''Last Order date: 2021.10.01''' | ||
+ | * '''End Of Production date: 2022.01.01''' | ||
+ | * '''End of Bug-Fixing date: 2023.07.01''' | ||
+ | * '''End Of Support date: 2024.01.01''' | ||
===2019.12.13: Top Sticker/Tampography Changes=== | ===2019.12.13: Top Sticker/Tampography Changes=== |
Latest revision as of 14:34, 16 July 2021
Main Page > Accessories > TSM232
This Product is started transition to EOL and will be discontinued by 2022.01.01:
- Last Order date: 2021.10.01
- End Of Production date: 2022.01.01
- End of Bug-Fixing date: 2023.07.01
- End Of Support date: 2024.01.01
Teltonika TSM232 is the Iridium SATELLITE terminal with a backup battery. The full solution combines Teltonika TSM232 with Teltonika FM63XY, FMB630, or FMB640 connected via RS232. This solution allows transferring data to a server via the Iridium satellite network when other terrestrial networks are unavailable. High capacity internal Ni-MH battery ensures long autonomous working hours when the main power source is disconnected. Such a solution meets the demand for high-security logistics, marine transport, construction & mining transport, oil/gas industry, public safety, government/defense, and more.
Basic characteristics
Features:
- Data transferring via Iridium satellite network when GSM network is unavailable
- Smart RS232 communication algorithm
- One FM63XY/FMB630/FMB640 message size forwarded to TSM232 is only 14bytes
- Message contains: Time/Coordinates/Speed/DIN1-4/DOUT1-2/Event ID
- Data sending can be initiated by periodic time interval or by panic priority event Specification:
- Iridium satellite transceiver 9603
- CPU STM32F103VDH6
Interface:
- RS232
- External Iridium antenna
- Internal Ni-MH backup rechargeable battery 7.2V 400mAh
- External power input DC 10-30V
- USB
- Digital input
- Analog input
- Digital output
Technical Information about internal battery
Internal backup battery | Battery voltage
(V) |
Nominal capacity (mAh) | Power(Wh)(mAh) | Charging temperature (°C) | Standard discharge temperature (°C) |
---|---|---|---|---|---|
Ni-MH Prismatic Battery pack | 7,2 ~7,5 | 400 | 2,95 – 3,07 | Ambient Temperature: 20±5 | Ambient Temperature: 20±5 |
Technical characteristics
PARAMETER | VALUE | ||||
---|---|---|---|---|---|
Minimum | Typical | Maximum | Unit | ||
Supply Voltage | |||||
Supply Voltage (Recommended Operating Conditions) | +10 | +30 | V | ||
Digital Output (Open Drain grade) | |||||
Drain current (Digital Output OFF) | 120 | μA | |||
Drain current (Digital Output ON, Recommended Operating Conditions) | 500 | mA | |||
Static Drain-Source resistance (Digital Output ON) | 120 | mΩ | |||
Digital Input | |||||
Input resistance (DIN1) | 59,9 | kΩ | |||
Input Voltage (Recommended Operating Conditions) | 0 | 60 | V | ||
Input Voltage threshold (DIN1) | 7,5 | 7,7 | 8 | V | |
Analog Input | |||||
Input Voltage (Recommended Operating Conditions), Range1 | 0 | 10 | V | ||
Input resistance, Range1 | 120 | kΩ |
Additional specifications:
- Input current/power specification - 1 A Max.
- Use 3A, 125V external fuse.
- Internal fuse specifications: Quick-acting; Rated current: 3A; Rated Breaking Capacity: 50A @ AC/DC 125V.
- The device uses SELV limited power source. The nominal voltage is 12 V DC. The allowed range of voltage is 10 V...30 V DC.
TSM232 Current consumption from battery
Mode/Voltage battery | 12 V | 7.2 V |
---|---|---|
Disconnected RS232 | 23.575 | 37.736 |
Connected RS232 (0 min send) with SIM (sleep) | 8.246 | 14.994 |
Connected RS232 (1 min send) | 19.808 | 30.473 |
Certification & Approvals
FAQ
YouTube
Product Change Notifications
2020.06.29: TSM232 END OF LIFE Announcement
The product End of Life (EOL) announcement signifies that a product has entered the final phase of Teltonika Product Life Cycle. Announcement serves as an advance notice of product termination in accordance with Teltonika EOL policy. Nevertheless, there is still enough time for you to order and get support that you need for the products that will be discontinued. Please contact your sales manager for more information.
EOL Plan:
- Last Order date: 2021.10.01
- End Of Production date: 2022.01.01
- End of Bug-Fixing date: 2023.07.01
- End Of Support date: 2024.01.01
2019.12.13: Top Sticker/Tampography Changes
We would like to inform you, that sticker changed to tampography of TSM232 Satellite terminals and was updated in the factory on the 13th of December.
Change description | ||
---|---|---|
Change type | External/visual | |
Detailed description | Top Sticker/Tampography design changed | |
Old Sticker Version: |
New Tampography Version: | |
Change reasons | 1. The Sticker was changed to Tampography 2. Added Teltonika address label Saltoniskiu st. 9B-1 3. Added WEEE label. (WEEE - Waste from Electrical and Electronic Equipment) 4. Added EAC label. (EAC - Eurasian Conformity mark) 5. Added E25 label. (E25 - E-Mark is the regulations issued by the Economic Commission for Europe) 6. Added CE label. (CE - certification mark that indicates conformity with health, safety, and environmental protection standards) | |
Product release date | Updated tampography will be used from the time when the stock will be sold all leftovers. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
TSM232 | TSM232******* | No changes |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change | |
Suggested implementation plan | No implementation plan needed |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |
To download the pdf version of this notification, click here.
2019.07.10: new eco friendly box
Effective July 2019 week 28, TSM232 Satellite terminals will be packed with a new eco-friendly box.
Change description | ||
---|---|---|
Change type | Packaging | |
Detailed description | Improved and more environmentally friendly packaging box | |
Old version: |
New version: | |
Change reasons | The new box is better for the environment | |
Product release date | July 2019, week 28 |