FMC650 CAN adapters
FMC650 supports CAN adapters over RS232 connection. CAN adapter support is added from 02.02.11.Rev.00 firmware
Easy steps to install and configure following CAN adapters on FMC650 device:
Installing CAN adapter with FMC650 device
Installing LV-CAN200 / ALL-CAN300
You can watch LV-CAN200 / ALL-CAN300 installation video in our YouTube channel here or follow connection instructions below.
Tools needed for installation
- LV-CAN200 or ALL-CAN300
- Connection scheme (Please contact Teltonika Sales Representative and provide information about vehicle manufacturer, model and year.
- FMC650 device
- Pliers
- Quick splice connectors (If vehicle CAN bus wires are very thin CAN adapter wires should be connected directly)
- Plastic pry tool
- Zip ties
Installation steps
- Be ready with a vehicle connection scheme that you have received from a Teltonika Sales Representative.
- Check the scheme for the current vehicle connection. Look for connectors matching PINs numbers and colors (maybe different) according to the connection scheme.
- Connect CAN adapter with FMC650:
- Connect CAN adapter's RS232 to RJ45 of FMC650.
- Connect CAN adapter CAN wires (CAN L, CAN H) as specified in connection scheme.
Do not swap CAN L and CAN H lines.
Not all CAN adapter wires may be used in the vehicle. - Connect CAN adapter positive and ground wires to the vehicle power supply lines or near FMC650 power wires.
Do not swap power supply lines.
Make sure that voltage does not exceed 30V. - Switch vehicle ignition to ACC position. CAN adapter LED diode on the back should start blinking.
- Configure CAN adapter to read CAN bus data or control vehicle by setting its program number - CAN Adapter configuration
Installing LV-CAN200 / ALL-CAN300 + ECAN02
Tools needed for installation
- LV-CAN200 / ALL-CAN300
- Connection scheme (Please contact Teltonika Sales Representative and provide information about vehicle manufacturer, model and year.
- ECAN02 (Used for contactless connection. If two CAN lines need to be connected, ECAN02 must be used.)
- FMC650 device
- Pliers
- Quick splice connectors (If vehicle CAN bus wires are very thin CAN adapter wires should be connected directly)
- Plastic pry tool
- Zip ties
Installation steps
- Follow the same 1, 2, 3 installation steps as with LV-CAN200 installation.
- Connect the appropriate CAN bus pair of wires between the CAN adapter and ECAN02:
- If CAN1 line need to be connected as specified in the connection scheme:
- If CAN2 line need to be connected as specified in the connection scheme:
- Fasten ECAN02 on vehicle CAN bus wires according to the connection scheme. Make sure CAN H and CAN L of vehicle corresponds to CAN H, CAN L markings on ECAN02 PCB.
- Connect CAN adapter positive and ground wires to the vehicle power supply lines or near FMC650 power wires.
Do not swap power supply lines.
Make sure that voltage does not exceed 30V. - Configure CAN adapter to read CAN bus data by setting its program number - CAN Adapter configuration
CAN Adapter Configuration
CAN Adapter program number selection
CAN Adapter must be set to the program number which depends on the vehicle model. Needed program number is always written on CAN Adapter mounting scheme. In order to be able to enter the program number in the adapter Software date of the CAN adapter must be newer than the connection scheme date. CAN adapter Software date can be checked:
- Via Teltonika Configurator→Status→CAN Adapter
- Via SMS command - lvcangetinfo
The number of digits required to enter the correct Program No. may vary depending on the Software and manufacture date of your CAN Adapter:
Entering via SMS command
Required conditions:
- CAN adapter properly connected to FMC650 device
CAN adapter program number can be set remotely, using an SMS command. Send following SMS command to FMC650 device:
- If you have set SMS login and password:
login pass lvcansetprog X
- If SMS login and password are not set leave two spaces before the command:
lvcansetprog X
Command example: lvcansetprog 11434
SMS response: LVCAN ProgNum: 11434
If during SMS command FMC650 was in the following Sleep mode:
- GPS Sleep - Program No. will be set immediately.
- Deep Sleep - Program No. will be set after the device wakes up.
- Online Deep Sleep - Program No. will be set immediately.
Entering via Teltonika Configurator
Required conditions:
- CAN adapter properly connected to FMC650 device
CAN adapter program number can be set via Teltonika Configurator → LVCAN → Program Number. When the program number is entered press Save to device button that saves the entered program number into FMC650.
Entering manually
Required conditions:
- CAN adapter properly connected to FMC650 device
- Vehicle ignition must be ON
Depending on the used CAN Adapter, the length of the setup sequence will vary.
Steps to set program number:
For ALL-CAN300 LV-CAN200 3 digit |
For ALL-CAN300 LV-CAN200 4 digit |
For ALL-CAN300 LV-CAN200 5 digit |
1. Hold SWITCH down until LED stars blink. |
2. Release the SWITCH. | |||
3. Then the LED starts blinking and counting the first digit of the program number (one blink means digit 1, two blinks mean digit 2, etc). To stop the counter, push SWITCH. | |||
4. Release the SWITCH, then the LED starts blinking and counting the second digit of the program number. To stop the counter, push SWITCH. | |||
5. Release the SWITCH, then the LED starts blinking and counting the third digit on the program number. To stop the counter, push SWITCH. | |||
6. Release the SWITCH, then the LED starts blinking and counting the fourth digit on the program number. To stop the counter, push SWITCH. | |||
7. Release the SWITCH, then the LED starts blinking and counting the fifth digit on the program number. To stop the counter, push SWITCH. | |||
All Devices | 8. Release SWITCH, if programming is successful LED will blink 10 times. |
Send data with 0 if the ignition is off
Depending on CAN Adapter I/O parameters and ignition status, FMC650 can send locked (last known) CAN Adapter I/O and active (real-time) parameter values or reset values to 0. When the ignition is off, CAN Adapter I/O parameters values sent to the server are:
CAN Adapter I/O element | Status |
---|---|
Vehicle Speed | reset |
Accelerator pedal position | reset |
Total fuel used | lock |
Fuel level (liters) | lock |
Engine RPM | reset |
Total mileage | lock |
Fuel level (%) | lock |
Program number | lock |
Module ID | lock |
Engine Work Time | lock |
Engine Work Time (counted) | lock |
Total Mileage (counted) | lock |
Fuel Consumed (counted) | lock |
Fuel Rate | reset |
Program number | lock |
AdBlue Level (%) | lock |
AdBlue Level (liters) | lock |
Engine Load | reset |
Engine Temperature | active |
Axle 1 Load | lock |
Axle 2 Load | lock |
Axle 3 Load | lock |
Axle 4 Load | lock |
Axle 5 Load | lock |
Control State Flags | active |
Agricultural Machinery Flags | active |
Harvesting Time | lock |
Area of Harvest | reset |
Mowing Efficiency | active |
Grain Mown Volume | active |
Grain Moisture | active |
Harvesting Drum RPM | reset |
Gap Under Harvesting Drum | active |
Security State Flags | active |
Tachograph Total Vehicle Distance | lock |
Trip Distance | reset |
Tachograph Vehicle Speed | reset |
Tachograph Driver Card Presence | active |
Driver1 States | active |
Driver2 States | active |
Driver1 Continuous Driving Time | active |
Driver2 Continuous Driving Time | active |
Driver1 Cumulative Break Time | active |
Driver2 Cumulative Break Time | active |
Driver1 Selected Activity Duration | active |
Driver2 Selected Activity Duration | active |
Driver1 Cumulative Driving Time | active |
Driver2 Cumulative Driving Time | active |
SMS Configuration
All CAN Adapter IO elements can be configured remotely via SMS commands.
SMS/GPRS Commands
CAN Adapters have several dedicated SMS/GPRS commands.
SMS command structure:
<SMS login><space><SMS password><space><command><space><value>
SMS command lvcangetinfo example:
- If you have set SMS login and password:
login pass lvcangetinfo
- If SMS login and password are not set leave two spaces before the command:
aalvcangetinfo
GPRS commands require Codec 12 protocol.
For more SMS commands please see SMS/GPRS command list
COMMAND | DESCRIPTION | RESPONSE |
---|---|---|
lvcansetprog # | Set program number to CAN Adapter that is connected to FMC650. # - three digit number that identity vehicle. |
Yes |
lvcansimpletacho # | Add or remove simpletacho start byte. # - 0 or 1 (0 – don’t add start byte, 1 – add start byte). |
No |
lvcangetprog | Get program number from CAN Adapter that is connected to FMC650. | Yes |
lvcangetinfo | Get information about connected CAN Adapter | Yes |
lvcanclear # | Clear Total Mileage (counted), Engine Work Time (counted), Fuel Consumed (counted) parameters values. # - parameter (0 – Engine work time (counted), 1 – Fuel Consumed (counted), 2 – Vehicle Mileage (counted)). |
Yes |
CAN Adapter State Flags
CAN Adapters receive data about the states of various systems within the vehicle, and send them as flags to FMC650. FMC650 device stores these flags in hexadecimal format, as one variable. Note! To retrieve all flags, Firmware version 03.00.16.Rev.01 for FMx650 / FMx641 or newer must be used. Below are the table of flags that are kept by LV-CAN200, ALL-CAN300 and information how to retrieve them:
Security State Flags P4
Byte | Bit | Value bitmasks | LVCAN | ALLCAN |
---|---|---|---|---|
0 | 0 | 0x00 – CAN1 connected, currently no data is received 0x01 – CAN1 connected, currently data is received 0x02 – CAN1 not connected, needs connection 0x03 – CAN1 not connected does not need connection |
✔ | ✔ |
0 | 2 | 0x00 – CAN2 connected, currently no data is received 0x01 – CAN2 connected, currently data is received 0x02 – CAN2 not connected, needs connection 0x03 – CAN2 not connected does not need connection |
✔ | ✔ |
0 | 4 | 0x00 – CAN3 connected, currently no data is received 0x01 – CAN3 connected, currently data is received 0x02 – CAN3 not connected, needs connection 0x03 – CAN3 not connected does not need connection |
||
1 | 8 | 0x01 – ignition on | ✔ | ✔ |
1 | 9 | 0x02 – key in ignition lock | ✔ | |
1 | 10 | 0x04 – Webasto | ✔ | |
1 | 11 | 0x08 – engine is working | ✔ | |
1 | 12 | 0x10 – standalone engine | ✔ | |
1 | 13 | 0x20 – ready to drive | ✔ | |
1 | 14 | 0x40 – engine is working on CNG | ✔ | ✔ |
1 | 15 | 0x80 – work mode (0 – private, 1 – company) | ✔ | |
2 | 16 | 0x01 – operator is present | ✔ | |
2 | 17 | 0x02 – interlock active | ✔ | |
2 | 18 | 0x04 – handbrake is active | ✔ | |
2 | 19 | 0x08 – footbrake is active | ✔ | |
2 | 20 | 0x10 – clutch is pushed | ✔ | |
2 | 21 | 0x20 – status of the hazard warning lights switch active | ✔ | |
2 | 22 | 0x40 – front left door opened | ✔ | ✔ |
2 | 23 | 0x80 – front right door opened | ✔ | ✔ |
3 | 24 | 0x01 – rear left door opened | ✔ | ✔ |
3 | 25 | 0x02 – rear right door opened | ✔ | ✔ |
3 | 26 | 0x04 – trunk door opened | ✔ | ✔ |
3 | 27 | 0x08 – engine cover opened | ✔ | ✔ |
3 | 28 | 0x10 – charging wire is plugged | ✔ | |
3 | 29 | 0x20 – battery charging on | ✔ | |
3 | 30 | 0x40 – electric engine is working | ✔ | |
3 | 31 | 0x80 – car is closed with factory remote control | ✔ | |
4 | 32 | 0x01 – car is closed | ✔ | |
4 | 33 | 0x02 – factory installed alarm is active | ✔ | |
4 | 34 | 0x04 – emulated alarm is active | ✔ | |
4 | 35 | 0x08 – signal of closing with factory remote control was sent | ✔ | |
4 | 36 | 0x10 – signal of opening with factory remote control was sent | ✔ | |
4 | 37 | 0x20 – rearm signal was sent | ✔ | |
4 | 38 | 0x40 – trunk was opened with remote control | ✔ | |
4 | 39 | 0x80 – CAN module is in SLEEP mode | ✔ | ✔ |
5 | 40 | 0x01 – signal of closing with factory remote control was sent 3 times | ✔ | |
5 | 41 | 0x02 – parking is active | ✔ | |
5 | 42 | 0x04 – reverse is active | ✔ | |
5 | 43 | 0x08 – neutral is active | ✔ | |
5 | 44 | 0x10 – drive is active | ✔ | |
5 | 45 | 0x20 – engine lock active | ||
5 | 46 | 0x40 – request to lock the engine (activation after attempt to restart the engine) | ||
5 | 47 | 0x80 – factory armed | ||
6 | 48 | 0x01 - roof opened | ✔ | ✔ |