FMB640 Mobileye

From Wiki Knowledge Base | Teltonika GPS
Main Page > EOL Products > FMB640 > FMB640 Configuration > FMB640 Mobileye

FMB640 devices supports Mobileye data. This data could be sent to server as other AVLelements. In order to do that you need to connect and set configuration for FMB640 correctly. This document describes how to connect FMB64 device to Mobileye unit.

NOTE: there is few different Mobileye module modifications and it might not be described in this document for more detailed information ask for Mobileye support. FMB640 devices uses CAN1 for Mobileye to FM communications. You need to connect this CAN bus interface to Mobileye dedicated CAN bus interface for FMS units.

Mobileye and FMB640 devices communicates through CAN bus. FMB640 CAN1 bus is dedicated for Mobileye to FM communication. As described in Mobileye documentation default baud rate is 500 Kbps. Select Autobaudrate or 500 kbps CAN1 bus speed from FMB640 configurator external devices tab.

FMB640 mobileye.png

Physical connection to Mobileye 5 CAN-A port

The Mobileye 5 CAN interface (CAN Bus) is located in the Main unit (SeeQ/camera). The Typical SeeQ CAN Channel dedicated for FMS Integrations and similar communication is CAN-A channel. You need to connect your FMB640 CAN1 interface to this connector. In Mobileye 5 the CAN-A Channel is accessible for physical connection using the CAN-A Male connector, (6 Pins connector labeled “EyeCAN”) in the Mobileye 5 main harness.

FMB64 device CAN1 H signal must be connected to „EyeCAN“ Pin1 and CAN1 L to Pin2. Please take a note that connectors for FMS devices (in this case FM64) are not suplied. This connection cable should be provided for FMB64 CAN1 connection with Mobileye 5 „EyeCAN“ port. [[Category:FMB640