ECAN02 is contactless adapter used to read vehicle CAN Bus data. ECAN02 adapter should be used in combination with:

It reads can-bus data through the isolation of wires without damaging them and forwards signals to the tracking device.

Features

  • ECAN02 collects vehicle data from CAN bus without damaging the wires
  • Powered from an on-board power source
  • Reads the signals through the isolation of CAN bus wires
  • Easy to install and operate

YouTube

ECAN02 Promo.png

Installing ECAN02 FMX150.png

Technical features

PARAMETER VALUE
Minimum Typical Typical Maximum Unit
Supply Voltage
Supply Voltage (Recommended Operating Conditions) +10 +12 +24 +30 V
Current Consumption
Working Mode 4.21 mA
Sleep Mode 1.47 mA
Operating Temperature
Operating Temperature -40 +85 °C
Protection
Internal resettable fuse (max 33 V) 750 mA
  • Dimensions 39 x 12 x 19 mm
  • CAN-BUS speeds up to 1000 kb/s
  • Fuse is protecting devices from high current peaks. If the voltage exceeds 33V (i.e. 35V) then protection diode stabilizes device voltage to 33V and the current value will increase accordingly.

Pinout

PIN NUMBER PIN NAME

DESCRIPTION

1 CAN L (Blue) Connect to CAN L input of CAN BUS converter
2 CAN H (White/Blue) Connect to CAN H input of CAN BUS converter
3 VCC (RED) Power supply (10-30) V DC (+)
4 GND (-) (Black) Ground wire (10-30) V DC (-)
ECAN01 pinout-01.png

Wiring scheme

ECAN02 wiring scheme.png

Setup ECAN02

  1. Gently open the ECAN02 cover using a plastic pry tool from both sides.
  2. Remove backing material on double-sided adhesive tape.
  3. Insert CAN wires. Please make sure that the correct slots are used (CAN High/CAN Low).
  4. Close the device.
  5. Device is ready-to-use.


ECAN02 (dvipusė įklijuojama) 01.png ECAN02 (dvipusė įklijuojama) 02.png ECAN02 (dvipusė įklijuojama) 03.png ECAN02 (dvipusė įklijuojama) 04.png ECAN02 (dvipusė įklijuojama) 05.png

Certification & Approvals

Memberships

Certification & Approvals

Nomenclature, classification codes

FAQ

Product Change Notifications

ECAN02 Product Change Notifications

Promotional Material

ECAN02 Promotional Material

Downloads

Manuals & Documentation

Pdf icon.png ECAN02 Datasheet (EN) (Updated on: 2023-06-21)
Pdf icon.png ECAN02 flyer (Updated on: 2023-06-22)
Pdf icon.png ECAN01 vs ECAN02 flyer (Updated on: 2023-06-22)

Additional information

ECAN02 Teltonika

For EOL policy please refer to link here.