FMB640 Parameter list
From Wiki Knowledge Base | Teltonika GPS
Main Page > EOL Products > FMB640 > FMB640 Manual > FMB640 Parameter list
System parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
102 | Uint8 | 2 | 0 | 3 | 0 – Disabled | Movement source |
1 – GPS Sleep | ||||||
2 – Deep Sleep | ||||||
3 – Online Deep Sleep | ||||||
103 | Uint8 | 10 | 1 | 3000 | Minutes | Sleep timeout |
106 | Uint8 | 1 | 0 | 1 | Mode | Static Navigation |
1003 | Uint8 | 0 | 0 | 1 | Mode | Save records to |
111 | Uint8 | 1 | 0 | 1 | Mode | Analog input value range |
114 | Uint8 | 1 | 0 | 1 | Mode | Analog Input Value Range 3-4 |
115 | Uint8 | 0 | 0 | 1 | Mode | AIN4/DOUT4 |
116 | Uint8 | 0 | 0 | 1 | Mode | J1708 settings |
117 | Uint8 | 0 | 0 | 4 | Mode | Odometer Source Settings |
118 | Uint8 | 0 | 0 | 4 | Mode | Speed Source settings |
107 | Uint8 | 1 | 0 | 1 | Mode | Saving/Sending without (TS) time synchronization |
1004 | Uint8 | 0 | 0 | 2 | Mode | Ping mode |
1005 | Uint8 | 60 | 0 | 259200 | Minutes | Ping timeout (min.) |
109 | Uint8 | 3 | 1 | 3 | 0 - Disable | GNSS Source |
1 - GPS only | ||||||
2 - GLONASS only | ||||||
3 - GPS + GLONASS | ||||||
101 | Uint8 | 32 | 1 | 63 | Mode | Ignition settings |
104 | Uint16 | 30000 | 0 | 30000 | Millivolts | Sets High voltage level |
105 | Uint16 | 13200 | 0 | 29999 | Millivolts | Low voltage level |
19001 | Uint8 | 1 | 1 | 60 | Seconds | Movement Start Delay(s) |
19002 | Uint16 | 60 | 5 | 60 | Seconds | Movement Stop Delay(s) |
900 | Uint8 | 1 | 0 | 3 | GPS only | Synchronization settings |
1 – NITZ and NTP | ||||||
2 – NTP | ||||||
3 – NITZ | ||||||
901 | Uint8 | 0 | 0 | 24 | Hours | NTP Resync |
902 | S8[55 | avl1.teltonika.lt | 0 | 55 char string | Char string | NTP server 1 |
903 | S8[55 | pool.ntp.org | 0 | 55 char string | Server address | NTP server 2 |