Difference between revisions of "FMB640 Parameter list"

From Wiki Knowledge Base | Teltonika GPS
Line 216: Line 216:
 
| style="text-align: center; vertical-align: center;" rowspan=1 |NTP server 2
 
| style="text-align: center; vertical-align: center;" rowspan=1 |NTP server 2
 
|-
 
|-
 
+
<br/><br/>
 
==GPRS parameters==
 
==GPRS parameters==
  
Line 319: Line 319:
 
| style="text-align: center; vertical-align: center;" rowspan=1 |SIM2 APN Password
 
| style="text-align: center; vertical-align: center;" rowspan=1 |SIM2 APN Password
 
|-
 
|-
! style="text-align: center; vertical-align: center;" rowspan=1 |Server #1 Domain
+
! style="text-align: center; vertical-align: center;" rowspan=1 |2004
 
| style="text-align: center; vertical-align: center;" rowspan=1 |S8[55]
 
| style="text-align: center; vertical-align: center;" rowspan=1 |S8[55]
 
| style="text-align: center; vertical-align: center;" rowspan=1 |Empty
 
| style="text-align: center; vertical-align: center;" rowspan=1 |Empty

Revision as of 13:24, 29 May 2018

Main Page > EOL Products > FMB640 > FMB640 Manual > FMB640 Parameter list


System parameters



GPRS parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
102 Uint8 2 0 3 0 – Disabled Movement source
1 – GPS Sleep
2 – Deep Sleep
3 – Online Deep Sleep
103 Uint8 10 1 3000 Minutes Sleep timeout
106 Uint8 1 0 1 Mode Static Navigation
1003 Uint8 0 0 1 Mode Save records to
111 Uint8 1 0 1 Mode Analog input value range
114 Uint8 1 0 1 Mode Analog Input Value Range 3-4
115 Uint8 0 0 1 Mode AIN4/DOUT4
116 Uint8 0 0 1 Mode J1708 settings
117 Uint8 0 0 4 Mode Odometer Source Settings
118 Uint8 0 0 4 Mode Speed Source settings
107 Uint8 1 0 1 Mode Saving/Sending without (TS) time synchronization
1004 Uint8 0 0 2 Mode Ping mode
1005 Uint8 60 0 259200 Minutes Ping timeout (min.)
109 Uint8 3 1 3 0 - Disable GNSS Source
1 - GPS only
2 - GLONASS only
3 - GPS + GLONASS
101 Uint8 32 1 63 Mode Ignition settings
104 Uint16 30000 0 30000 Millivolts Sets High voltage level
105 Uint16 13200 0 29999 Millivolts Low voltage level
19001 Uint8 1 1 60 Seconds Movement Start Delay(s)
19002 Uint16 60 5 60 Seconds Movement Stop Delay(s)
900 Uint8 1 0 3 GPS only Synchronization settings
1 – NITZ and NTP
2 – NTP
3 – NITZ
901 Uint8 0 0 24 Hours NTP Resync
902 S8[55 avl1.teltonika.lt 0 55 char string Char string NTP server 1
903 S8[55 pool.ntp.org 0 55 char string Server address NTP server 2
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1002 Uint8 0 0 1 Mode Sorting
1000 Uint32 30 259200 30 Seconds Open Link Timeout
1001 Uint16 30 5 300 Seconds Server Response Timeout
2000 Uint8 1 0 1 Mode SIM1 GPRS content activation
2001 S8[32] Empty 0 32 char string Text SIM1 APN Name
2002 S8[30] Empty 0 30 char string Text SIM1 APN username
2003 S8[30] Empty 0 30 char string Text SIM1 APN Password
2011 Uint8 1 0 1 Mode SIM2 GPRS content activation
2012 S8[32] Empty 0 32 char string Text SIM2 APN Name
2013 S8[30] Empty 0 30 char string Text SIM2 APN username
2014 S8[30] Empty 0 30 char string Text SIM2 APN Password
2004 S8[55] Empty 0 55 char string Internet address Server #1 Domain
2005 Uint16 0 0 65535 Port number Target Server #1 Port
2006 Uint8 0 0 1 Mode Server #1 Protocol
2007 S8[55] Empty 0 55 char string Internet address Server #2 Server Domain
2008 Uint8 0 0 65535 Port number Server #2 Server Port
2009 Uint8 0 0 1 Mode 2nd Server Protocol
13003 Uint8 1 0 1 Mode FOTA WEB status
13000 S8[55] 85.206.140.106 0 55 char string Internet address FOTA WEB Domain
13001 Uint8 5000 0 65535 Port number FOTA WEB port
13002 Uint16 720 30 65535 Minutes FOTA WEB Period (min)