FMB640 Parameter list

From Wiki Knowledge Base | Teltonika GPS
Main Page > EOL Products > FMB640 > FMB640 Manual > FMB640 Parameter list


System parameters

Sleep Mode (ID=102)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 3 2 Sleep timeout (ID=103) Uint8

Sleep timeout (ID=103)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
1 3000 10 Sleep Mode (ID=102) Uint8

Static Navigation (ID=106)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 1 1 Static Navigation Settings (ID=112) Uint8

Save records to (ID=1003)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 1 0 Uint8

Analog input value range (ID=111)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 1 1 Uint8

Analog Input Value Range 3-4 (ID=114)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 1 1 Uint8

AIN4/DOUT4 Mode (ID=115)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 1 0 Uint8

J1708 settings (ID=116)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 1 0 Uint8

Speed Source settings (ID=118)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 4 0 Uint8

Saving/Sending without (TS) time synchronization (ID=107)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 1 1 Uint8

Ping mode (ID=1004)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 2 0 Uint8

Ping timeout (min.)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 259200 60 Uint8

GNSS Source (ID=109)

1 – GPS only 2 – GLONASS only 3 – GPS + GLONASS

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
1 3 3 Uint8

Ignition settings (ID=101)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
1 63 32 High voltage level (ID=104)
Low voltage level (ID=105)
Movement Start Delay(s) (ID=19001)
Movement Stop Delay(s) (ID=19002) Uint8

High voltage level (ID=104)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0
(but higher than low level) 30000 30000 Ignition settings (ID=101)
Low voltage level (ID=105)
Uint16

Low voltage level (ID=105)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 29999 (but lower than high level) 13200 Ignition settings (ID=101)
High voltage level (ID=104)
Uint16

Movement Start Delay(s) (ID=19001)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
1 60 1 Ignition settings (ID=101)
Movement Stop Delay(s) (ID=19002) Uint8

Movement Stop Delay(s) (ID=19002)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
5 60 60 Ignition settings (ID=101)
Movement Start Delay(s) (ID=19001) Uint16

Synchronization settings (ID=900) Settings used for device internal time synchronization: 0 – GPS only, 1 – NITZ and NTP, 2 – NTP, 3 – NITZ.

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 3 1 NTP Resync (ID=901)
NTP server 1 (ID=902)
NTP server 2 (ID=903) Uint8

NTP Resync (ID=901)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 24 0 Synchronization settings (ID=900)
NTP server 1 (ID=902)
NTP server 2 (ID=903) Uint8

NTP server 1 (ID=902)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 55 char string avl1.teltonika.lt Synchronization settings (ID=900)
NTP Resync (ID=901)
NTP server 2 (ID=903) S8[55]

NTP server 2 (ID=903)

Minimum value Maximum value Default value Goes with (depends on) parameters Value type
0 55 char string pool.ntp.org Synchronization settings (ID=900)
NTP Resync (ID=901)
NTP server 1 (ID=902) S8[55]