Difference between revisions of "FM6300 CAN adapters"
m (Protected "FM6300 CAN adapters" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
m (Protected "FM6300 CAN adapters" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
(No difference)
|
Latest revision as of 22:34, 2 April 2020
Main Page > EOL Products > FM6300 > FM6300 Manual > FM6300 CAN adaptersEasy steps to install and configure following CAN adapters on FM6300 device:
Installing CAN adapter with FM6300 device
Installing LV-CAN200/ALL-CAN300
You can watch LV-CAN200/ALL-CAN300 installation video in our YouTube channel here or follow connection instructions below.
Tools needed for installation
- LV-CAN200/ALL-CAN300
- Connection scheme (Please contact Teltonika Sales Representative and provide information about vehicle manufacturer, model and year.
- FM6300 device
- Pliers
- Quick splice connectors (If vehicle CAN bus wires are very thin CAN adapter wires should be connected directly)
- Plastic pry tool
- Zip ties
Installation steps
- Be ready with a vehicle connection scheme that you have received from a Teltonika Sales Representative.
- Check the scheme for the current vehicle connection. Look for connectors matching PINs numbers and colors (maybe different) according to connection scheme.
- Connect CAN adapter with FM6300:
- Connect CAN adapter's MINI USB to USB of FM6300.
- Connect CAN adapter CAN wires (CAN L, CAN H) as specified in connection scheme.
Do not swap CAN L and CAN H lines.
Not all CAN adapter wires may be used in vehicle. - Connect CAN adapter positive and ground wires to the vehicle power supply lines or near FM6300 power wires.
Do not swap power supply lines.
Make sure that voltage does not exceed 30V. - Switch vehicle ignition to ACC position. CAN adapter LED diode on the back should start blinking.
- Configure CAN adapter to read CAN bus data or control vehicle by setting its program number - CAN Adapter configuration
Installing LV-CAN200/ALL-CAN300 + ECAN02
Tools needed for installation
- LV-CAN200/ALL-CAN300
- Connection scheme (Please contact Teltonika Sales Representative and provide information about vehicle manufacturer, model and year.
- ECAN02 (Used for contactless connection. If two CAN lines need to be connected, ECAN02 must be used.)
- FM6300 device
- Pliers
- Quick splice connectors (If vehicle CAN bus wires are very thin CAN adapter wires should be connected directly)
- Plastic pry tool
- Zip ties
Installation steps
- Follow the same 1, 2, 3 installation steps as with LV-CAN200/ALL-CAN300 installation.
- Connect the appropriate CAN bus pair of wires between the CAN adapter and ECAN02:
- If CAN1 line need to be connected as specified in the connection scheme:
- If CAN2 line need to be connected as specified in the connection scheme:
- Fasten ECAN02 on vehicle CAN bus wires according to the connection scheme. Make sure CAN H and CAN L of vehicle corresponds to CAN H, CAN L markings on ECAN02 PCB.
- Connect CAN adapter positive and ground wires to the vehicle power supply lines or near FM6300 power wires.
Do not swap power supply lines.
Make sure that voltage does not exceed 30V. - Configure CAN adapter to read CAN bus data by setting its program number - CAN Adapter configuration
CAN Adapter Configuration
CAN Adapter program number selection
CAN Adapter must be set to program number which depends on the vehicle model. Needed program number is always written on CAN Adapter mounting scheme. In order to be able to enter program number in adapter Software date of CAN adapter must be newer than connection scheme date. CAN adapter Software date can be checked:
- Via Teltonika Configurator→Status→CAN Adapter
- Via SMS command - lvcangetinfo
The number of digits required to enter correct Program No. may vary depending on the Software and manufacture date of your CAN Adapter:
Entering via SMS command
Required conditions:
- CAN adapter properly connected to FM6300 device
CAN adapter program number can be set remotely, using SMS command. Send following SMS command to FM6300 device:
- If you have set SMS login and password:
login pass lvcansetprog X
- If SMS login and password are not set leave two spaces before command:
lvcansetprog X
Command example: lvcansetprog 11434
SMS response: LVCAN ProgNum: 11434
If during SMS command FM6300 was in following Sleep mode:
- GPS Sleep - Program No. will be set immediately.
- Deep Sleep - Program No. will be set after device wake up.
- Online Deep Sleep - Program No. will be set immediately.
Entering via Teltonika Configurator
Required conditions:
- CAN adapter properly connected to FM6300 device
CAN adapter program number can be set via Teltonika Configurator → LVCAN → Program Number. When program number is entered press Save to device button that saves the entered program number into FM6300.
Entering manually
Required conditions:
- CAN adapter properly connected to FM6300 device
- Vehicle ignition must be ON
Depending on the used CAN Adapter, the length of the setup sequence will vary.
Steps to set program number:
|+
|-
| rowspan="5" style="border: 1px solid #0054A6; background: white; color: #0054A6; text-align: center; width:10%;" | For
ALL-CAN300
LV-CAN200
3 digit
| rowspan="6" style="border: 1px solid #0054A6; background: white; color: #0054A6; text-align: center; width:10%;" | For
ALL-CAN300
LV-CAN200
4 digit
| rowspan="7" style="border: 1px solid #0054A6; background: white; color: #0054A6; text-align: center; width:11%;" | For
LV-CAN200
5 digit
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white; width:38%;" |1. Hold SWITCH down until LED stars blinking.
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |2. Release the SWITCH.
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |3. Then LED starts blinking and counting first digit of program number (one blink means digit 1, two blinks mean digit 2 etc). To stop counter, push SWITCH.
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |4. Release the SWITCH, then LED starts blinking and counting second digit of program number. To stop counter, push SWITCH.
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |5. Release the SWITCH, then LED starts blinking and counting third digit on program number. To stop counter, push SWITCH.
|-
| rowspan="2" style="border: 1px solid white; border-bottom: 1px solid #0054A6; background: white;" |
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |6. Release the SWITCH, then LED starts blinking and counting fourth digit on program number. To stop counter, push SWITCH.
|-
| style="border: 1px solid white; border-bottom: 1px solid #0054A6; background: white;" |
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |7. Release the SWITCH, then LED starts blinking and counting fifth digit on program number. To stop counter, push SWITCH.
|-
| colspan="3" style="border: 1px solid #0054A6; background: white; color: #0054A6; text-align: center;" | All Devices
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |8. Release SWITCH, if programming is successful LED will blink 10 times.
|}
Send data with 0, if ignition is off
Depending on CAN Adapter I/O parameters and ignition status, FM6300 can send locked (last known) CAN Adapter I/O and active (real time) parameters values or reset values to 0. When ignition is off, CAN Adapter I/O parameters values sent to server are:
CAN Adapter I/O element | Status |
---|---|
Vehicle Speed | reset |
Accelerator pedal position | reset |
Total fuel used | lock |
Fuel level (liters) | lock |
Engine RPM | reset |
Total mileage | lock |
Fuel level (%) | lock |
Program number | lock |
Module ID | lock |
Engine Work Time | lock |
Engine Work Time (counted) | lock |
Total Mileage (counted) | lock |
Fuel Consumed (counted) | lock |
Fuel Rate | reset |
Program number | lock |
AdBlue Level (%) | lock |
AdBlue Level (liters) | lock |
Engine Load | reset |
Engine Temperature | active |
Axle 1 Load | lock |
Axle 2 Load | lock |
Axle 3 Load | lock |
Axle 4 Load | lock |
Axle 5 Load | lock |
Control State Flags | active |
Agricultural Machinery Flags | active |
Harvesting Time | lock |
Area of Harvest | reset |
Mowing Efficiency | active |
Grain Mown Volume | active |
Grain Moisture | active |
Harvesting Drum RPM | reset |
Gap Under Harvesting Drum | active |
Security State Flags | active |
Tachograph Total Vehicle Distance | lock |
Trip Distance | reset |
Tachograph Vehicle Speed | reset |
Tachograph Driver Card Presence | active |
Driver1 States | active |
Driver2 States | active |
Driver1 Continuous Driving Time | active |
Driver2 Continuous Driving Time | active |
Driver1 Cumulative Break Time | active |
Driver2 Cumulative Break Time | active |
Driver1 Selected Activity Duration | active |
Driver2 Selected Activity Duration | active |
Driver1 Cumulative Driving Time | active |
Driver2 Cumulative Driving Time | active |
SMS Configuration
All CAN Adapter IO elements can be configured remotely via SMS commands.
SMS/GPRS Commands
CAN Adapters have several dedicated SMS/GPRS commands.
SMS command structure:
<SMS login><space><SMS password><space><command><space><value>
SMS command lvcangetinfo example:
- If you have set SMS login and password:
login pass lvcangetinfo
- If SMS login and password are not set leave two spaces before command:
aalvcangetinfo
GPRS commands require Codec 12 protocol.
For more SMS commands please see SMS/GPRS command list
COMMAND | DESCRIPTION | RESPONSE |
---|---|---|
lvcansetprog # | Set program number to CAN Adapter that is connected to FM6300. # - three digit number that identity vehicle. |
Yes |
lvcansimpletacho # | Add or remove simpletacho start byte. # - 0 or 1 (0 – don’t add start byte, 1 – add start byte). |
No |
lvcangetprog | Get program number from CAN Adapter that is connected to FM6300. | Yes |
lvcangetinfo | Get information about connected CAN Adapter | Yes |
lvcanclear # | Clear Total Mileage (counted), Engine Work Time (counted), Fuel Consumed (counted) parameters values. # - parameter (0 – Engine work time (counted), 1 – Fuel Consumed (counted), 2 – Vehicle Mileage (counted)). |
Yes |
lvcanfaultcodes | Read DTC fault codes | Yes |
CAN Adapter State Flags
CAN Adapters receive data about the states of various systems within the vehicle, and send them as flags to FM6300. FM6300 device stores these flags in hexadecimal format, as one variable. Below is a list of kept flags and how to retrieve them.
The full list of state flags is stored only by:
Property name | Size, bytes | Value bitmasks |
---|---|---|
Control state flags | 4 | Byte0 (LSB): 0x01 – STOP |
Agricultural machinery flags | 8 | Byte0 (LSB): 0x01 – Mowing |
Security state flags | 8 | Byte0 (LSB): 0x01 – CAN1 not connected, require connection |
Tachograph driver card presence | 1 | 0x00 – No driver card 0x01 – Driver1 card presence |
Driver 1 states | 1 | 0xX0 – Break/rest 0xX1 – Availability |
Driver 2 states | 1 |
LV-CAN200/ALL-CAN300 Important Information
Program Number logic change
Due to the growing number of supported cars, program numbers have exceeded "999". In order to maintain one number format, we are moving from 3-digit to 4-digit program numbers.
In new LV-CAN200/ALL-CAN300 firmware (from 2017-09-01) all program numbers that were up to 999 are changed to start from 1000. So that further program numbers would continue the counting with 4-digit numbers.
However, all existing program numbers stay the same, but "1" is added to the front. The device still understands the entered 3-digit program number (via SMS/GPRS), it will automatically add "1" before it. If you enter "247" - device number will turn into "1247". In Bootloader only 4-digit format is available, just add "1" to the front of the needed program number.
Example
When using older connection schemes where the program number displayed as 3-digit program number:
Using LV-CAN200/ALL-CAN300 Bootloader from soft version 2017-09-27 it is necessary to add "1" to the front of the program number: